play arrow-right linkedin-icon facebook-icon chevron-down close envelop facebook twitter
Call now

Wide Range.
Affordable.

EcoPod Exterior

EcoPod

Our Standard Cylinder

EcoPod standard copper cylinders are available in a wide range of specifications.

The copper cylinders are available in three grades – Grade 1, Grade 2 and Grade 3, with Grade 3 generally being selected for normal domestic use, i.e. water with a PH of 7.5.

ecopod-long life Grades 1 & 2 are made from heavier material and are most often used where there is a greater working head of water or where improved durability is required.

Grades 1 & 2 are made from heavier material and are most often used where there is a greater working head of water or where improved durability is required.

Contact us now

Test Pressure & Maximum Working Head

Grade 1:

Test Pressure:

3.65bar

Max. Working Head:

25m

(82 feet)

Grade 2:

Test Pressure:

2.2bar

Max. Working Head:

15m

(49 feet)

Grade 3:

Test Pressure:

1.45bar

Max. Working Head:

10m

(33 feet)

Advantages of the EcoPod?

Smaller and larger units available icon

Smaller and larger units available

Connections can be positioned to suit icon

Connections can be positioned to suit

Tools icon

Simple and easy to install

EcoPod Features
No maintenance required icon

No maintenance required

100% recyclable

100% recyclable

Long life icon

Long life

Direct or Indirect
Well Water Compatible

Why Choose Copper?

Recycled copper meets 42% of the European copper demand, using only 15% of the energy required in extracting new raw materials, making it sustainable, environmentally friendly and the most recycled plumbing material available today.

Copper also has a long and established history of being used in conveying clean, safe drinking water because of its natural antibacterial properties and inherent health benefits making it a well trusted, tried and tested material for water supply and storage.

Copper is a well-known, trusted, corrosion resistant. With great benefits.

100%

Recyclable material
Health Benefits Health benefits

The Ecopod Range:

Direct Cylinder Illustration

Direct Cylinder

Direct Cylinder Illustration

Direct Economy 7/E.S.B. Gold Shield

Direct Cylinder Illustration

Indirect/Direct

Direct Cylinder Illustration

Indirect

Direct Cylinder Illustration

Indirect Twin Coil

Direct Cylinder Illustration

Indirect Triple Coil

Direct Cylinder

EcoPod Direct Cylinder

Direct Economy

EcoPod Direct Economy

Indirect/Direct

EcoPod Direct/Indirect

Indirect

EcoPod Indirect Cylinder

Indirect Twin Coil

EcoPod Indirect Twin Coil Cylinder

Indirect Triple Coil

EcoPod Indirect Triple Coil Cylinder
  • A - 1" Female hot out
  • B - Direct flow or back boiler connection
  • C - Direct return connection
  • D - 2 1/4 Immersion boss
  • E - Cold feed
  • F - Coil return
  • G - Coil flow
Height from ground of screwed connections
Cylinder Reference Number B.S. Ref. Net Capacity Volume (ltrs) Max Operating Temp (bar) Dimensions Exc. Insulation (mm) (D) (C&E) (F)
EP 72 1 72 1.0 900x350mm 700mm 100mm 400mm
EP 96 1 96 1.0 900x400mm 700mm 100mm 400mm
EP 114 3 114 1.0 1050x400mm 800mm 100mm 470mm
EP 84 4 84 1.0 675x450mm 450mm 100mm 300mm
EP 84 4 84 1.0 675x450mm 450mm 100mm 300mm
EP 95 5 95 1.0 750x450mm 550mm 100mm 340mm
EP 106 6 106 1.0 825x450mm 625mm 100mm 370mm
EP 106 6 106 1.0 825x450mm 625mm 100mm 370mm
EP 117 7 117 1.0 900x450mm 100mm 100mm 400mm
EP 120* 120* 1.0 900x450mm
EP 140 8 140 1.0 1050x450mm 800mm 100mm 470mm
EP 144* 144* 1.0 1050x450mm
EP 162 9 162 1.0 1200x450mm 950mm 100mm 540mm
EP 166* 166 1.0 1200x450mm
EP 206 9E 206 1.0 1500x450mm 1200mm 100mm 620mm
EP 210 210 1.0 1500x450mm
EP 190 10 190 1.0 1200x500mm 950mm 150mm 540mm
EP 245 11 245 1.0 1500x500mm 1200mm 150mm 670mm
EP 280 12 280 1.0 1200x600mm 950mm 150mm 540mm
EP 360 13 360 1.0 1500x600mm 1200mm 150mm 670mm
EP 440 14 440 1.0 1800x600mm 1350mm 150mm 800mm

* To suit ‘Off Peak’ electric heating systems.

All of our cylinders can be customized to suit your needs. As well as our award-winning range of products, we also offer a custom 3D CAD design service allowing your exact specifications to be met.

Download the EcoPod Product Guide

Well Water
Compatible

EcoPod Combimation Unit

EcoPod Combination Unit

The Perfect Cylinder For Apartments

The EcoPod Combination Unit is primarily designed for apartments. This unit can deliver gravity fed or pumped hot and cold water supplies.

Each unit is comprised of a cold water storage tank mounted over an indirect copper cylinder (hot water storage), relevant isolation valves, electric immersion heaters complete with energy cut-out and internal feed and expansion piping.

The entire unit, except the cold water storage lid, is coated with 35mm of environmentally friendly foam insulation.

Contact us now

EcoPod Combination Unit Deluxe

The Perfect Cylinder For Apartments

The EcoPod Combination Unit Deluxe combines a Grade 3 copper cylinder with a black polythene cold feed tank and is a complete steel-framed unit with inter-connecting pipework. These units offer a practical and efficient solution where space and easy installation are an important factor.

Available as indirect and direct, the direct comes with two side entry immersion heaters. All units have 227 ltrs cold storage tanks.

Contact us now
EcoPod Combimation Unit Dexlue

Combination Unit

EcoPod Combination Unit Specifications

Combination Unit Deluxe

EcoPod Combination Unit Deluxe Specifications
  • A - 3/4 inch copper expansion pipe
  • B - 25 mm approved polyurethane insulation
  • C - 1/2 inch drain cock
  • D - 1 inch coil connection
  • E - Overflow warning pipe connects here
  • F - Cold feed to copper hot water cylinder
  • G - Cold water supply from storage tank to pump
  • H - Hot water supply from cylinder to pump
  • I - Immersion heater
  • J -Indirect flow
  • K - Indirect return
  • L - Drain cock
  • M - Expansion tank
  • N - Cold water storage tank
  • O - Steel frame
  • P - Cold mains supply

EcoPod Combination Unit

Cylinder Reference Number Capacity Cold / Hot Type Overall Diameter Overall Height Cold Tank Height Hot Tank Height
EPC 227/120 227 / 120 Indirect
ESB Type
500
530
2170
2170
1300
1300
870
870
EPC 227/144 227 / 144 Indirect
ESB Type
550
580
2140
2140
1300
1300
840
840
EPC 317/120 317 / 120 Indirect
ESB Type
583
613
2180
2180
1560
1560
620
620
EPC 317/144 317 / 144 Indirect
ESB Type
650
680
1850
1850
1260
1260
590
590
EPC 317/180 317 / 180 Indirect
ESB Type
650
680
1990
1990
1260
1260
730
730
EPC 314/120 314 / 120 Indirect
ESB Type
583
613
2280
2280
1660
1660
620
620

EcoPod Combination Unit Deluxe

Cylinder Reference Number Cylinder Size H x D Overall Height (mm) Overall Width (mm) Overall Depth (mm) Capacity (Ltrs) Indirect Capacity (Ltrs) Direct
EPCD 117/120 900 x 450 2050 600 600 117 120
EPCD 140/144 1050 x 450 2050 600 600 140 144
EPCD 162/166 975 x 500 2050 600 600 162 166
EPCD 205/210 1050 x 500 2050 600 600 205 210

All of our cylinders can be customized to suit your needs. As well as our award-winning range of products, we also offer a custom 3D CAD design service allowing your exact specifications to be met.

Download The Combination Units Product Guide